Features
The MIMOlite Module is an interface / bridge module, capable of converting a digital or analog voltage input and/or a Z-WaveTM RF message input to a dry contact relay output and/or a Z-WaveTM RF message output. MIMOlite comes in a plastic enclosure for indoor use only.
- Connect one wired devices to Signal input and make them wireless.
- Connect them functionally to your Home Security panel OR to your z-wave home automation network
- Connect high or low up to 16V digital signals
- Connect pulse reading devices
- Connect up to 16V analog signals
The MIMOlite module provides one input and one relay output (isolated dry contacts, NO-COM-NC) and is capable of Z-WaveTM input/output/control. The system includes a program switch for Z-WaveTM inclusion/exclusion and an LED for various status indications.
Input SIG1 is an analog input, internally pulled-up to the MIMOlite supply voltage. The system allows trigger conditions to be set based on the input voltage being inside or outside a user-defined range (configured via Z-Wave). This provides great flexibility for capturing events in a wide variety of applications. The trigger status of the input can be read via Z-WaveTM and/or can be automatically sent to a configured node, typically the Controller. In addition, a count of the trigger events that have occurred for each input channel are internally recorded (and stored in the 'pulse count') and are available to be read via Z-Wave. The current triggered/un-triggered status can also be read via Z-Wave. The SIG1 input can be associated with up to two other Z-WaveTM devices, such that an associated device will automatically turn on (or off) based on the occurrence of a trigger event. Finally, the analog input channels can be configured so that they periodically send the analog input level (not just trigger status) to up to two other associated nodes.
The output relay is, typically, commanded via Z-WaveTM commands. In addition, the user can configure the input SIG1 trigger condition to be mapped to the output relay. Thus, for example, Relay 1 can be automatically turned on based on Input SIG1 being triggered.
The relay activation can be set via a jumper or via ZWave for either momentary or latched operation - see Installation section of the User Manual.
Shipping Note: Shipping to Alaska, Hawaii, P.O. Boxes, and APO addresses is not available for this item
Warranty: 90 Day Woot Limited Warranty
Specs
Power: 9-16 V DC from a power supply @~ 300mA capability
Frequency Range: 908.4MHz (US); 868.4MHz (EU)
Distance Range: Max 100ft line of sight in unobstructed environment
Enclosure Size (L x W x D): 3 3/8" (85mm) x 2 1/2" (64mm) x 1 1/4" (30mm)
Weight: 4 oz (100 gram)
Operating Temperature: -10⁰C (14F) to +70⁰C (158F)
Input Signal 1 (SIG1): Digital or Analog Input 0 to 16V DC or 16 Hz Max for pulse counting (minimum 32 ms high or low time). The trigger levels and hysteresis can be set via the Configuration Command Class for the two endpoints.
Input Signal Impedance Input impedance for SIG1 is Z=66 ohm at 10KHz. This impedance is = 66 ohm = 34 ohm + j 540uH.
Output Relay 1: DPDT, Max. Switching power of 120W; 10uA to 10A; High Dielectric strength coil-contacts: 1,000 VAC;
Open contacts: 750 VAC; Conforms to FCC Part 68 requirements; Ag + Au clad bifurcated contacts fully sealed.
System Requirement: Any Z-WaveTM -enabled network and controller.
* FCC and Canada IC certified for 908.4 MHZ Z-Wave RF communications.
* Complies with European Test standard: ETSI EN 300 220 for 868.4 MHZ Z-Wave RF communications.
Specs
Power: 9-16 V DC from a power supply @~ 300mA capability
Frequency Range: 908.4MHz (US); 868.4MHz (EU)
Distance Range: Max 100ft line of sight in unobstructed environment
Enclosure Size (L x W x D): 3 3/8" (85mm) x 2 1/2" (64mm) x 1 1/4" (30mm)
Weight: 4 oz (100 gram)
Operating Temperature: -10⁰C (14F) to +70⁰C (158F)
Input Signal 1 (SIG1): Digital or Analog Input 0 to 16V DC or 16 Hz Max for pulse counting (minimum 32 ms high or low time). The trigger levels and hysteresis can be set via the Configuration Command Class for the two endpoints.
Input Signal Impedance Input impedance for SIG1 is Z=66 ohm at 10KHz. This impedance is = 66 ohm = 34 ohm + j 540uH.
Output Relay 1: DPDT, Max. Switching power of 120W; 10uA to 10A; High Dielectric strength coil-contacts: 1,000 VAC;
Open contacts: 750 VAC; Conforms to FCC Part 68 requirements; Ag + Au clad bifurcated contacts fully sealed.
System Requirement: Any Z-WaveTM -enabled network and controller.
* FCC and Canada IC certified for 908.4 MHZ Z-Wave RF communications.
* Complies with European Test standard: ETSI EN 300 220 for 868.4 MHZ Z-Wave RF communications.
Sales Stats
- Speed to First Woot:
- 1d 19h 45m 8.448s
Purchaser Experience
Purchaser Seniority
Quantity Breakdown
Percentage of Sales Per Hour
12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
---|
Percentage of Sales Per Day
Mon | Tue | Wed | Thu | Fri | Sat | Sun |
---|
Woots by State
Best sellers
-
(NEW) Neat Bumblebee II Professional Cardioid USB Condenser Microphone$1699 $99.9983% off Reference Price
-
Apple Watch Braided Solo Loop - Black, White Hues$2999 $99.0070% off Reference Price
-
Samsung 15W Wireless Fast Charger Duo Pad$1999 $69.9571% off Reference Price
-
Apple Watch Braided Solo Loop - Blue Hues$2999 $99.0070% off Reference Price